ELISA分析底物
Microplate Readers
Biochrom EZ Read LED Microplate Reader
The EZ Read LED microplate reader delivers fast and reliable measurement performance using LEDs coupled to high quality interference filters for light source and wavelength selection. Novel LED technologyprovides worry-free operation without compromising on measurement performance. THe EZ Read LED is PC-controlled using new, intuitive Galapagos software for data acquisition and analysis. A great choice for busy ELISA labs, EZ Read LED is also available as a UV version for measurements at 340nm.
Galapagos for EZ Read Software"s ‘click and drag" approach makes usability a key feature.
- Create new plate layouts
- Add multiple assays to a plate
- Add multiple plates per analysis
- Easy to create new methods.
- Select only the data you want for data reporting
- Windows 7 & 8 compatibility as well as older Windows OS from XP.
- So easy you won"t need to export your data into Excel.
EZ Read LED Microplate Reader:
- Measures one 96-well plate in 5 seconds
- Automatic calibration adn reference channel ensure measure performance
- Measures flat, u-bottom, v-bottom 96-well plates
Biochrom EZ Read LED Microplate Reader has 4 pre-installed LEDs for measuring ELISA assays:
ELISA Assay Substrate | Filter |
NPP, ABTS | 405nm |
OPD | 490nm |
Slow TMB, Turbo TMB, Ultra TMB | 450nm |
Reference wavelength | 620nm |
A LED at 340nm can be opted for measurment of NADH/NADPHassays
Ordering infromation:
Product Description | Order Code |
Biochrom EZ ReadLED Microplate Reader with Galapagos for EZ Read Software | 80-4002-10 |
Biochrom EZ ReadLED UVMicroplate Reader with Galapagos for EZ Read Software | 80-4002-11 |
Specification | Data |
---|---|
Lamp Source | LED |
Measurement Range | 0-4.0 OD |
Reproducibility/Precision | 0.5% and 0.005OD to 3.5OD |
Accuracy | <=1% and 0.005 to 3.5OD |
Standard Filters | 405, 450, 492, 620nm LED |
Wavelength Selection | LED |
Wavelength Range | 340- 900nm |
Plate Types | flat, round and v-bottomed 96-well plates |
Data Output | Export to PC |
Detection System | 8 silicon photodiodes |
Reading Speed | 5 Seconds |
Software | Galapagos Software |
Shaking | 4 speed standard |
Temperature Control | None |
Linearity | 0.5% and 0.005OD to 3.5OD |
Computer Interface | USB 2.0 |
Optical System | LED |
Power Requirement | 24VDC, 2.5A |
Validation | |
Wavelength Reproducibility (+/-) | |
Wavelength Accuracy (+/-) | |
Dimensions (WxDxH) | 360x515x315 mm |
Weight | 12.4 kg |
Mode of Operation | PC Control |
Analysis Software | Galapagos Software |